the UK power grid is weird. mostly due to echoes of the war. used to be that, to save copper, the entire house and sometimes multiple houses on a street would be wired as one big loop of wire, no fuse box or anything. that's where the individually fused plugs and switched sockets come from. then, since it turned out to be quite a good idea for safety, they kept doing it.
Allows you to remove power from the plugged in device without unplugging it. This provides convenience to easily and quickly turn things on and off and prevents arcing when unplugging. 240V 13A can arc a bit, particularly if unplugged under load, or on older sockets where the contacts have worn. While a little arcing doesn't do much damage immediately, over time it will cause pitting and make a high resistance joint that will generate heat.
The switch only disconnects the live terminal, but the neutral terminal should be similar potential to earth (depending on how the building is wired).
Truly the king of plugs and sockets. The plugs are individually fused according to the device needs, ergonomic to use and exciting to stand on.
I like them, personally. You don't have to use them but they are sometimes handy. I just spent 30 seconds feeling around a TV to turn it off only to discover it doesn't have buttons. Killed it at the wall.
It's not a deal breaker, in any case. The weird foreign convention I would like to shame is doors that require a key to open from the inside.
As any cautious parent could tell you, these are helpful when the toddler starts sticking things in places where they don't belong. Such as metal cutlery. In the power sockets.
Kind of off topic, but I've just gotta add that the safety shutters over the positive and negative terminals that only open when the ground pin (which is longer than the others on the plug) is inserted up top is brilliant, it basically makes short circuiting impossible. Electrical outlet design is one of the few things I'll concede the UK does better than the rest of the world.
UK household electricity is pretty spicy compared to many other places - it has more safety features as a result. (3 pinned fused plug, socket switches etc)
Great for turning off a device or several devices without having to unplug (e.g. if the sockets are behind a bookcase, this is much more convenient). Not a super common need but when it saves moving furniture it helps. Given that UK switches are tougher to plug in and unplug than most (due to safety features), I prefer using a switch. Also, the switches are cheap and give more options, so may as well!
I rely on one for a light where the switch broke and wasn't easily replaceable, so being able to fall back on the mains switch meant I can keep using the light.
I like the integration of the switch, should be standard. I use many switch plug-ins just to avoid stand-by consumption (it really adds up over the year) and to avoid high pitch humming on some devices.
YSK: there's also remote controls for these switches, very handy
Being a uk person its cause they can & its also in to building / electric code.
Its just a switch that breaks the live leg, stops sparking when plugging in stuff.
No one seemed to mention the important fact that UK and I think most Europe is a higher voltage than the US. Tom Scott as well as Technology Connections have some good videos on the whys and differences it causes.
Safety and convenience versus the cost of including them, I expect.
The Wikipedia page for BS 1363 says they're optional and weren't added to the standard until 1967. I can't recall having seen a domestic socket without one.
But it seems the only legal way to read the actual standard is to pay for it, and even the HSE website isn't much help.
when any electricity leaks out (for example through your body) it switches off. the eu also has the same system, but its one switch for your entire house. the us also has this but only in bathrooms.
at least in part it's an end result of decades of crud and tech debt, so to speak, accumulating in british power grid and home wiring. they do it this way because otherwise it won't be safe. continental euro home wiring usually has thicker wires, residual-current circuit breakers and no ring circuits so we get away without fuzes and switches, and with smaller plugs that don't become caltrops. sometimes we do have ring circuits kind of thing, but not in house wiring, instead it's in medium voltage distribution grid, and it's sized so that it can serve most of loads after single failure.
explanation
in normal state, medium voltage line (like 15kV, 20kV) might branch out in rural terrain from substation to two or more places. in case of single failure, mildly common after storms, everything downstream would be down. instead, to increase reliability, every few km there's a radio-controlled switch and some of the far ends have line between them that is usually disconnected. in case of single failure, damaged segment is cut off, and the far end of the loop switch gets closed. this way power is delivered the long way around the loop, allowing for repairs of the damaged sector in the meantime. this also specifically avoids some of problems of ring circuits especially in situation when some lines might be damaged.